This script search US Code. View Rule
Menu Item - Home
Menu Item - Agenda Main page
Menu Item - Historical Agenda
Menu Item - Historical Agenda
Menu Item - Agenda Search
Menu Item - EO Dashboard
Menu Item - Reg Review
Menu Item - EO Agency lists
Menu Item - EO Search
Menu Item - EO Historical Reports
Menu Item - Review Counts
Menu Item - OIRA Letters
Menu Item - EOM 12866 Search
Menu Item - EO XML Reports
Menu Item - ICR Dashboard page
Menu Item - ICR Main page
Menu Item - ICR Search
Menu Item - ICR XML Reports
Menu Item - FAQ
Menu Item - Additional Resources
Menu Item - Contact Us
Search: Agenda Reg Review ICR
       Search

View Rule

View EO 12866 Meetings Printer-Friendly Version     Download RIN Data in XML

EPA/AR RIN: 2060-AP08 Publication ID: Spring 2013 
Title: Revisions to Test Method for Determining Stack Gas Velocity Taking Into Account Velocity Decay Near the Stack Walls 
Abstract: This action revises the voluntary test method for determining volumetric gas flow taking into account the velocity decay near the stack or duct walls. The current method addresses only sources where the flow measurements are made in locations with circular cross-sections. This revised test method addresses flow measurement locations with both circular and rectangular cross-sections increases the accuracy of the method and simplifies its application. The primary users of the method are owners and operators of utility units subject to the Acid Rain program and large electric generating units and large non-generating units that are subject to the nitrogen oxide State Implementation Plan call. 
Agency: Environmental Protection Agency(EPA)  Priority: Substantive, Nonsignificant 
RIN Status: Previously published in the Unified Agenda Agenda Stage of Rulemaking: Final Rule Stage 
Major: No  Unfunded Mandates: No 
CFR Citation: 40 CFR 60 
Legal Authority: Clean Air Act title I 
Legal Deadline:  None
Timetable:
Action Date FR Cite
NPRM  08/25/2009  74 FR 42819 
Final Rule  12/00/2013   
Additional Information: Docket #:EPA-HQ-OAR-2008-0697
Regulatory Flexibility Analysis Required: No  Government Levels Affected: None 
Small Entities Affected: No  Federalism: No 
Included in the Regulatory Plan: No 
Sectors Affected: 221112 Fossil Fuel Electric Power Generation 
RIN Data Printed in the FR: No 
Agency Contact:
Jason Dewees
Environmental Protection Agency
Air and Radiation
E143-02,
Research Triangle Park, NC 27711
Phone:919 541-9724
Fax:919 541-0516
Email: dewees.jason@epa.gov

Conniesue Oldham
Environmental Protection Agency
Air and Radiation
D205-02, E143-02,
Research Triangle Park, NC 27711
Phone:919 541-7774
Fax:919 541-0516
Email: oldham.conniesue@epa.gov

 
About Us   Vertical Spacer Spacer Related Resources   Vertical Spacer Spacer Disclosure   Vertical Spacer Spacer Accessibility   Vertical Spacer Spacer Privacy Policy   Vertical Spacer Spacer Contact Us