<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<REGINFO_RIN_DATA xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" RUN_DATE="2026-11-24-05:00" xsi:noNamespaceSchemaLocation="https://www.reginfo.gov/public/xml/REGINFO_XML_Ver10262011.xsd">
    <RIN_INFO>
        <RIN>1219-AA75</RIN>
        <PUBLICATION>
            <PUBLICATION_ID>199804</PUBLICATION_ID>
            <PUBLICATION_TITLE>Unified Agenda of Federal Regulatory and Deregulatory Actions</PUBLICATION_TITLE>
        </PUBLICATION>
        <AGENCY>
            <CODE>1219</CODE>
            <NAME>Mine Safety and Health Administration</NAME>
            <ACRONYM>MSHA</ACRONYM>
        </AGENCY>
        <PARENT_AGENCY>
            <CODE>1200</CODE>
            <NAME>Department of Labor</NAME>
            <ACRONYM>DOL</ACRONYM>
        </PARENT_AGENCY>
        <RULE_TITLE>Longwall Equipment (Including High-Voltage)</RULE_TITLE>
        <ABSTRACT><![CDATA[Since 1970, MSHA regulations have required that high-voltage cables and transformers be kept at least 150 feet from the coal extraction area. The objective of this requirement is to prohibit the use of high-voltage cables and equipment that could serve as an ignition source for methane and coal dust in close proximity to the work area. ^PThe modern development of highly productive longwall mining systems has resulted in their widespread use in the mining industry. Mine operators, however, currently must apply to MSHA for a variance from the existing standards in order to use this high-voltage equipment. The increased use of high-voltage longwalls in underground coal mines in recent years has led to the design of safe high-voltage electrical equipment and associated cables. These improvements have occurred specifically in the area of design and construction of explosion-proof equipment; insulation, short circuit, ground fault, and mechanical protection of cables; and equipment for safe handling of cables. For these reasons, in August 1992, MSHA published a proposed rule to establish safety requirements for the design, construction, installation, use, and maintenance of high-voltage longwall equipment and associated cables. The final rule will eliminate the need for a variance to use this equipment.]]></ABSTRACT>
        <PRIORITY_CATEGORY>Other Significant</PRIORITY_CATEGORY>
        <RIN_STATUS>Previously Published in The Unified Agenda</RIN_STATUS>
        <RULE_STAGE>Final Rule Stage</RULE_STAGE>
        <MAJOR>No</MAJOR>
        <UNFUNDED_MANDATE_LIST>
            <UNFUNDED_MANDATE>No</UNFUNDED_MANDATE>
        </UNFUNDED_MANDATE_LIST>
        <CFR_LIST>
            <CFR>30 CFR 18</CFR>
            <CFR>30 CFR 75</CFR>
        </CFR_LIST>
        <LEGAL_AUTHORITY_LIST>
            <LEGAL_AUTHORITY>30 USC 811</LEGAL_AUTHORITY>
            <LEGAL_AUTHORITY>30 USC 957</LEGAL_AUTHORITY>
        </LEGAL_AUTHORITY_LIST>
        <RPLAN_ENTRY>No</RPLAN_ENTRY>
        <TIMETABLE_LIST>
            <TIMETABLE>
                <TTBL_ACTION>NPRM</TTBL_ACTION>
                <TTBL_DATE>08/27/1992</TTBL_DATE>
                <FR_CITATION>57 FR 39036</FR_CITATION>
            </TIMETABLE>
            <TIMETABLE>
                <TTBL_ACTION>NPRM Comment Period End</TTBL_ACTION>
                <TTBL_DATE>11/13/1992</TTBL_DATE>
                <FR_CITATION>57 FR 46350</FR_CITATION>
            </TIMETABLE>
            <TIMETABLE>
                <TTBL_ACTION>Reopen Record</TTBL_ACTION>
                <TTBL_DATE>10/18/1995</TTBL_DATE>
                <FR_CITATION>60 FR 53891</FR_CITATION>
            </TIMETABLE>
            <TIMETABLE>
                <TTBL_ACTION>Extension of Comment Period</TTBL_ACTION>
                <TTBL_DATE>11/14/1995</TTBL_DATE>
                <FR_CITATION>60 FR 57203</FR_CITATION>
            </TIMETABLE>
            <TIMETABLE>
                <TTBL_ACTION>Comment Period Closed</TTBL_ACTION>
                <TTBL_DATE>12/18/1995</TTBL_DATE>
                <FR_CITATION>60 FR 57203</FR_CITATION>
            </TIMETABLE>
            <TIMETABLE>
                <TTBL_ACTION>Final Action</TTBL_ACTION>
                <TTBL_DATE>10/00/1998</TTBL_DATE>
            </TIMETABLE>
        </TIMETABLE_LIST>
        <ADDITIONAL_INFO>MSHA reopened the record on October 18, 1995. The comment period finally closed on December 18, 1995.</ADDITIONAL_INFO>
        <RFA_REQUIRED>No</RFA_REQUIRED>
        <GOVT_LEVEL_LIST>
            <GOVT_LEVEL>None</GOVT_LEVEL>
        </GOVT_LEVEL_LIST>
        <PRINT_PAPER>NA</PRINT_PAPER>
        <INTERNATIONAL_INTEREST>Not Collected</INTERNATIONAL_INTEREST>
        <AGENCY_CONTACT_LIST>
            <CONTACT>
                <FIRST_NAME>Patricia</FIRST_NAME>
                <LAST_NAME>Silvey</LAST_NAME>
                <MIDDLE_NAME>W.</MIDDLE_NAME>
                <TITLE>Director, Office of Standards, Regulations, and Variances</TITLE>
                <AGENCY>
                    <CODE>1219</CODE>
                    <NAME>Mine Safety and Health Administration</NAME>
                    <ACRONYM>MSHA</ACRONYM>
                </AGENCY>
                <PHONE>202 693-9440</PHONE>
                <FAX>202 693-9441</FAX>
                <EMAIL>silvey.patricia@dol.gov</EMAIL>
                <MAILING_ADDRESS>
                    <STREET_ADDRESS>Room 631, 1100 Wilson Boulevard, Room 2350,</STREET_ADDRESS>
                    <CITY>Arlington</CITY>
                    <STATE>VA</STATE>
                    <ZIP>22209-3939</ZIP>
                </MAILING_ADDRESS>
            </CONTACT>
        </AGENCY_CONTACT_LIST>
        <PROCUREMENT>Not Procurement Related</PROCUREMENT>
        <REINVENT_GOVT>Revising Text to Reduce Burden or Duplication, or Streamline Requirements</REINVENT_GOVT>
    </RIN_INFO>
</REGINFO_RIN_DATA>