Skip to main content
An official website of the United States government
The .gov means it's official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you're on a federal government site.
The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.
Search:
Agenda
Reg Review
ICR
This script is used to control the display of information in this page.
Display additional information by clicking on the following:
All
Brief and OIRA conclusion
Abstract/Justification
Legal Statutes
Rulemaking
FR Notices/Comments
IC List
Burden
Misc.
Common Form Info.
Certification
View Information Collection (IC) List
View Supporting Statement and Other Documents
Please note that the OMB number and expiration date may not have been determined when this Information Collection Request and associated Information Collection forms were submitted to OMB. The approved OMB number and expiration date may be found by clicking on the Notice of Action link below.
View ICR - OIRA Conclusion
OMB Control No:
1219-0088
ICR Reference No:
201406-1219-005
Status:
Historical Active
Previous ICR Reference No:
201201-1219-001
Agency/Subagency:
DOL/MSHA
Agency Tracking No:
Title:
Ventilation Plans, Tests, and Examinations in Underground Coal Mines
Type of Information Collection:
Revision of a currently approved collection
Common Form ICR:
No
Type of Review Request:
Regular
OIRA Conclusion Action:
Approved with change
Conclusion Date:
11/06/2015
Retrieve Notice of Action (NOA)
Date Received in OIRA:
07/29/2015
Terms of Clearance:
Inventory as of this Action
Requested
Previously Approved
Expiration Date
11/30/2018
36 Months From Approved
11/30/2015
Responses
1,902,012
0
1,300,846
Time Burden (Hours)
313,624
0
232,726
Cost Burden (Dollars)
118,982
0
184,648
Abstract:
Under Section 101(a) of the Federal Mine Safety and Health Act of 1977 (the Mine Act), the Secretary may by rule in accordance with procedures set forth in this section and in accordance with section 553 of Title 5, United States Code (without regard to any reference in such section to sections 556 and 557 of such title), develop, promulgate, and revise as may be appropriate, improved mandatory health or safety standards for the protection of life and prevention of injuries in coal or other mines. In addition, Section 303 requires that all coal mines be ventilated by mechanical ventilation equipment installed and operated in a manner approved by an authorized representative of the Secretary and such equipment be examined daily and a record be kept of such examination. Underground coal mines usually present harsh and hostile working environments. The ventilation system is the most vital life support system in underground mining and a properly operating ventilation system is essential for maintaining a safe and healthful working environment. Lack of adequate ventilation in underground mines has resulted in fatalities from asphyxiation and explosions. An underground mine is a maze of tunnels that must be adequately ventilated with fresh air to provide a safe environment for miners. Methane is liberated from the strata, and noxious gases and dusts from blasting and other mining activities may be present. The explosive and noxious gases and dusts must be diluted, rendered harmless, and carried to the surface by the ventilating currents. Sufficient air must be provided to maintain the level of respirable dust at or below 2 milligrams per cubic meter of air and air quality must be maintained in accordance with MSHA standards. Mechanical ventilation equipment of sufficient capacity must operate at all times while miners are in the mine. Ground conditions are subject to frequent changes, thus sufficient tests and examinations are necessary to ensure the integrity of the ventilation system and to detect any changes that may require adjustments in the system. Records of tests and examinations are necessary to ensure that the ventilation system is being maintained and that changes which could adversely affect the integrity of the system or the safety of the miners are not occurring. These examination, reporting and recordkeeping requirements of §§ 75.310, 75.312, 75.342, 75.351, 75.360 through 75.364, 75.370, 75.371, and 75.382 also incorporate examinations of other critical aspects of the underground work environment such as roof conditions and electrical equipment which have historically caused numerous fatalities if not properly maintained and operated.
Authorizing Statute(s):
PL:
Pub.L. 91 - 173 101(a)
Name of Law: Federal Mine Safety and Health Act of 1977
Citations for New Statutory Requirements:
None
Associated Rulemaking Information
RIN:
Stage of Rulemaking:
Federal Register Citation:
Date:
Not associated with rulemaking
Federal Register Notices & Comments
60-day Notice:
Federal Register Citation:
Citation Date:
80 FR 20015
04/14/2015
30-day Notice:
Federal Register Citation:
Citation Date:
80 FR 45237
07/29/2015
Did the Agency receive public comments on this ICR?
No
Number of Information Collection (IC) in this ICR:
1
IC Title
Form No.
Form Name
Ventilation Plans, Tests and Examinations in Underground Coal Mines
ICR Summary of Burden
Total Approved
Previously Approved
Change Due to New Statute
Change Due to Agency Discretion
Change Due to Adjustment in Estimate
Change Due to Potential Violation of the PRA
Annual Number of Responses
1,902,012
1,300,846
0
601,166
0
0
Annual Time Burden (Hours)
313,624
232,726
0
80,898
0
0
Annual Cost Burden (Dollars)
118,982
184,648
0
0
-65,666
0
Burden increases because of Program Change due to Agency Discretion:
Yes
Burden Increase Due to:
Changing Regulations
Burden decreases because of Program Change due to Agency Discretion:
No
Burden Reduction Due to:
Short Statement:
Due to regulatory changes in the rule titled “Lowering Miners’ Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors, ” published May 1, 2014, there is an increase of 80,898 burden hours from the previously approved 232,726 hours to the current total request of 313,624 for ventilation plan development as well as certification of mine examinations.
Annual Cost to Federal Government:
$269,658
Does this IC contain surveys, censuses, or employ statistical methods?
No
Is the Supporting Statement intended to be a Privacy Impact Assessment required by the E-Government Act of 2002?
No
Is this ICR related to the Affordable Care Act [Pub. L. 111-148 & 111-152]?
No
Is this ICR related to the Dodd-Frank Wall Street Reform and Consumer Protection Act, [Pub. L. 111-203]?
No
Is this ICR related to the American Recovery and Reinvestment Act of 2009 (ARRA)?
No
Is this ICR related to the Pandemic Response?
Uncollected
Agency Contact:
Nicole Bouchet 202 646-2814 nicole.bouchet@dhs.gov
Common Form ICR:
No
On behalf of this Federal agency, I certify that the collection of information encompassed by this request complies with 5 CFR 1320.9 and the related provisions of 5 CFR 1320.8(b)(3).
The following is a summary of the topics, regarding the proposed collection of information, that the certification covers:
(a) It is necessary for the proper performance of agency functions;
(b) It avoids unnecessary duplication;
(c) It reduces burden on small entities;
(d) It uses plain, coherent, and unambiguous language that is understandable to respondents;
(e) Its implementation will be consistent and compatible with current reporting and recordkeeping practices;
(f) It indicates the retention periods for recordkeeping requirements;
(g) It informs respondents of the information called for under 5 CFR 1320.8 (b)(3) about:
(i) Why the information is being collected;
(ii) Use of information;
(iii) Burden estimate;
(iv) Nature of response (voluntary, required for a benefit, or mandatory);
(v) Nature and extent of confidentiality; and
(vi) Need to display currently valid OMB control number;
(h) It was developed by an office that has planned and allocated resources for the efficient and effective management and use of the information to be collected.
(i) It uses effective and efficient statistical survey methodology (if applicable); and
(j) It makes appropriate use of information technology.
If you are unable to certify compliance with any of these provisions, identify the item by leaving the box unchecked and explain the reason in the Supporting Statement.
Certification Date:
07/29/2015