| DOE/EE | RIN: 1904-AD93 | Publication ID: Fall 2024 |
| Title: Test Procedures for Air-Cooled, Evaporatively-Cooled, and Water- Cooled Commercial Package Air Conditioners and Heat Pumps | |
|
Abstract:
The U.S. Department of Energy (DOE) has amended the Federal test procedures for air-cooled commercial package air conditioners and heat pumps with a rated cooling capacity greater than or equal to 65,000 Btu/h, evaporatively-cooled commercial package air conditioners, and water-cooled commercial package air conditioners to incorporate by reference the latest versions of the applicable industry test standards. In the final rule, DOE has amended the current test procedure for this equipment for measuring the current cooling and heating metrics -- integrated energy efficiency ratio (IEER) and coefficient of performance (COP), respectively; and established a new test procedure for this equipment that adopts two new metrics -- integrated ventilation, economizer, and cooling (IVEC) and integrated ventilation and heating efficiency (IVHE). Testing to the IVEC and IVHE metrics will not be required until such time as compliance is required with any amended energy conservation standard based on the new metrics. Additionally, DOE amended certain provisions of DOE’s regulations related to representations and enforcement for the subject equipment. |
|
| Agency: Department of Energy(DOE) | Priority: Substantive, Nonsignificant |
| RIN Status: Previously published in the Unified Agenda | Agenda Stage of Rulemaking: Completed Actions |
| Major: No | Unfunded Mandates: No |
| CFR Citation: 10 CFR 431 | |
| Legal Authority: 42 U.S.C. 6314(a)(4)(B) 42 U.S.C. 6314(a)(1)(A) | |
Legal Deadline:
|
||||||||||||||||||||||||||||||
Timetable:
|
| Regulatory Flexibility Analysis Required: YES | Government Levels Affected: None |
| Small Entities Affected: Businesses | Federalism: No |
| Included in the Regulatory Plan: No | |
| RIN Information URL: https://www1.eere.energy.gov/buildings/appliance_standards/standards.aspx?productid=75&action=viewlive | |
| RIN Data Printed in the FR: Yes | |
| Related RINs: Related to 1904-AF45 | |
|
Agency Contact: Troy Watson Project Manager Department of Energy Energy Efficiency and Renewable Energy U.S. Department of Energy, 1000 Independence Avenue SW, Mail Stop EE-5B, Washington, DC 20585 Phone:240 449-9387 Email: troy.watson@ee.doe.gov |
|
An official website of the United States government